Maestro Software Manual The CANopen Configurator
MAN-MASSW (Ver. Q)
9-10
CAN bus baud rate (for bus 0 and bus 1) defines the baud rate for the
LSS master initialization during auto connection with the device. The
property is available only if the auto connect property is set to
YES.
Auto identification after connection to Maestro device defines the program
behavior when communication with the target Maestro device is established.
Enable auto identification by DS301 makes it possible to use the NMT
service of the DS301 protocol to automatically recognize a CAN node. If
the CAN bus is not configured, this option does not work correctly.
Enable auto identification by DS305 this feature makes it possible to use
the DS305 protocol to automatically recognize a specified CAN node. This
option can be used for CAN nodes with a unique LSS address. DS305
CAN node auto identification may not work correctly with a large CAN
bus (i.e., where there are more than 16 nodes).
If a CAN node is not located, the user can add the node manually, or
load it from a file. The new configuration must be stored with the File
> Node Set Import feature.
Disconnect from Maestro device defines how the program behaves when it
disconnects from the Maestro device.
Figure
9-17: Disconnect from a Maestro Device
Change Maestro resources after disconnect defines possible
changes to the resource file of the Maestro device. The changes
can be performed during the LSS master disconnection. The
user can choose either
YES or NO. (See Figure 9-17).
If the user selects
YES and changes the Node ID, the Maestro
restarts with an empty resource file. The Configurator gets the
current baud rate for CAN bus initialization.
If the user selects
NO, the Maestro restarts with the previous
resource file.
Configuration process parameters define the program behavior during the
CAN network configuration.
Immediate store configuration data defines the order of data
saved in the CAN nodes. This process is more time consuming
because it saves each node's data individually during the
configuration process.