Tuba Installation Guide Technical Specifications
MAN-TUBIG (Ver. 1.502)
www.elmomc.com
62
Emulated output of the resolver, interpolated analog encoder, Tachometer or
Potentiometer
Fast output compare (OC), optically isolated
4.1.7. Built-In Protection
Software error handling
Abort (hard stops and soft stops)
Status reporting
Protection against
Shorts between motor power outputs
Shorts between motor power output and power input/return
Failure of internal power supplies
Overheating
Over/Under voltage
Loss of feedback
Following error
Current limits
Protection against regenerated over-voltage (when using external DC Link)
DC-Linkage extends the limits of the built-in shunt and provides over voltage protection.