EO - Echo Mode
Purpose:
Sets or resets the communication echo mode, which is used for communication checks.
EO=1 enables echo mode
EO=0 disables it.
With RS-232 communication, the EO command sends an immediate echo character for
every terminal character. The echo transmission is deferred to the command response
string.
Attributes: Type: Parameter, Integer
Source: RS-232
Restrictions: None
Default value: 1, Volatile
Range: [0, 1]
Unit modes: All
Activation: Immediate
Note: Once the EO setting has been changed with a Terminal Program to EO=0, no
communication is possible over Composer.